CRANE OVERLOAD PROTECTION ELECTRONICS FOR 2 CHANNELS + SUM


OVERLOAD

CABIN-2xB1SUMD

The CABIN-2IB1SUMD and CABIN-2DB1SUMD are crane overload protection systems designed to manage 2 hoisting devices as well as the sum of the loads.

    x = input:
           - I: mV/V or
           - D: process input 4(0)...20 mA
o Display of hoisted loads and input signals
o Monitoring system of load cell integrity and electronics (fail safe)



AVAILABLE OPTIONS

- analogue output 4(0)...20 mA or 0...10 V
- RS-232, RS-485, USB or fieldbus capabilities
- NEMA 4X /IP67 (transparent protection cover - option "COVER PAX")
- power supply: 48 VAC / 24 VDC (see CABIN-2xB1SUMD2 products)
- stainless steel cabinet 
Add to basket
for quotation


Drop your files here
CABIN-2IB1SUMD CABIN-2IB1SUMD12 CABIN-2DB1SUMD CABIN-2DB1SUMD12
Type (-) Load limiter for dual 4..20mA load cell , Load limiter for dual 4...20 mA load cell , Load limiter for dual 4...20 mA load cell, Load limiter for dual 4..20mA load cell Load limiter for dual 4..20mA load cell , Load limiter for dual 4...20 mA load cell , Load limiter for dual 4...20 mA load cell, Load limiter for dual 4..20mA load cell Load limiter for dual 4..20mA load cell , Load limiter for dual 4...20 mA load cell , Load limiter for dual 4...20 mA load cell, Load limiter for dual 4..20mA load cell Load limiter for dual 4..20mA load cell , Load limiter for dual 4...20 mA load cell , Load limiter for dual 4...20 mA load cell, Load limiter for dual 4..20mA load cell
Input range (-)
± 24 mVDC / ± 240 mVDC ± 24 mVDC / ± 240 mVDC 20 mA (-2 to +26 mA) 20 mA (-2 to +26 mA)
Sensor excitation (-) 10 VDC @ 125 mA (max) 10 VDC @ 125 mA (max) 24 VDC ± 5 % @ 50 mA (max) 24 VDC ± 5 % @ 50 mA (max)
Display (-) 3 x 5 digits (14.2 mm) 3 x 5 digits (14.2 mm) 3 x 5 digits (14.2 mm) 3 x 5 digits (14.2 mm)
Accuracy (% F.S.*)
0.5 0.5 0.5 0.5
Service temperature range (°C)
0...+50 0...+50 0...+50 0...+50
Storage temperature range (°C)
-40...+60 -40...+60 -40...+60 -40...+60
Power supply (-)
85...250 VAC, 50/60 Hz (45 VA) 11...36 VDC (33 W) 24 VAC (45 VA) 85...250 VAC, 50/60 Hz (45 VA) 11...36 VDC (33 W) 24 VAC (45 VA)
Qty of relay (-) 2 x 3 + 4 2 x 3 +4 2 x 3 + 4 2 x 3 + 4
Relay type (-) "Form A"- potential free "Form A"- potential free "Form A"- potential free "Form A"- potential free
Contact rating (-) 3 A @ 250 VAC / 30 VDC 3 A @ 250 VAC / 30 VDC 3 A @ 250 VAC / 30 VDC 3 A @ 250 VAC / 30 VDC
IP rating (-)
IP54 IP54 IP54 IP54

* F.S. : Full Scale.
** : except thermal drifts.
Specifications subject to change without notice.

Typical applications
Download our leaflet

Associated electronics