ECONOMICAL CUSTOM-MADE LOAD PINS


ATEX CE LEVAGE CSA IECEX OVERLOAD

5600

Custom-made load pins designed to be installed at the same place of a common axle without change to the existing mechanical environment. Economical version of model 5000.

o Complete range of CE certified electronics, load limiters and displays available for hoisting applications and lifts
o Useful diameter smaller than or equal to 39 mm
o With axial cable gland
o Sturdy design
o Material: stainless steel
o Protection class: IP65
o Cable length: 6 m (other lengths available on request).

AVAILABLE OPTIONS

DUAL-BRIDGE
SIL-PL
AMPLIFIED-OUTPUT
EXi
-50+150
IP67
Get our
Standard Item
Do you have
specific need ?
Add to basket
for quotation


Drop your files here
SL - FORCE SL - HOIST
Combined error (non-linearity + hysteresis) (% F.S.*) 0.25 - 1 0.5 - 2
Repeatability error (% F.S.*) <± 0.25 <± 0.25
Creep error over 30 min. (% F.S.*)
<± 0.3 <± 0.3
Reference temperature (°C) 23 23
Compensated temperature range (°C) -10...+45 -10...+45
Service temperature range (°C)
-30...+70 -30...+70
Storage temperature range (°C)
-50...+85 -50...+85
Temperature coefficient of the sensitivity (% F.S.*/10°C) <± 0.2 <± 0.2
Temperature coefficient of zero signal (% F.S.*/10°C) <± 0.2 <± 0.2
Zero balance (mV/V)
± 0.02 ± 0.02
Nominal sensitivity (mV/V)
± 1.5 ± 1
Sensitivity tolerance (%) < ± 0.5 < ± 0.5
Input resistance (ohm(s)) 350 ± 2 350 ± 2
Output resistance (ohm(s)) 350 ± 2 350 ± 2
Insulation resistance (50 V) (Mohm(s)) > 5000 > 5000
Reference excitation voltage (VDC)
10 10
Permissible nominal range of excitation voltage (VDC) 3...12 3...12
Safe load limit (% F.S.*) 150 200
Breaking load (% F.S.*)
> 300 > 500
Permissible dynamic loading (% F.S.*)
50 75
Static lateral force limit (% F.S.*)
100 150

* F.S. : Full Scale.
** : except thermal drifts.
Specifications subject to change without notice.

Typical applications
Download our leaflet

Associated electronics