How to define different trigger thresholds from a button on our digital load limiters ?

QuestionHow to change the switching threshold on an INDI-PAXS through a switch or the F1 key

 

The PAXS has 2 lists of parameters, the main list and the auxiliary list, to go from one to the other by pressing F1 for example, it is necessary to go in the menu 2, and to give to F1, the function List. In this way, pressing F1 will display Load A and Load B respectively corresponding to main list and auxiliary list.

 

To set different thresholds, you just have to specify SP1 when you are in "LOAD A" mode and do the same after going into "Load B" mode.