CONDITIONERS - AMPLIFIERS FOR STRAIN-GAUGE-BASED TRANSDUCERS
COND-SGA
o Input: Wheatstone bridge 0.1 to 30 mV/V
o Output: 4(0)...20 mA, -10...0...+10 V
o Power supply:
- COND-SGA-A: 115...230 VAC / 18...24 VDC
- COND-SGA-D: 18...24 VDC
o Low-cost
o Enclosure: ABS case 164 x 84 x 57 mm
COND-SGA-A | COND-SGA-D | |
---|---|---|
Type (-) | Strain-gauge conditioner (mV/V) | Strain-gauge conditioner (mV/V) |
Input range (-)
|
0.1...30 mV/V | 0.1...30 mV/V |
Sensor excitation (-) | 5 / 10 VDC (Zmin. | 5 / 10 VDC (Zmin. |
Non-linearity error (% F.S.*)
|
< 0.03 | < 0.03 |
Low pass filter (Hz) | 1...5000 | 1...5000 |
Bandwidth (Hz)
|
DC...6000 | DC...6000 |
Service temperature range (°C)
|
-10...+50 | -10...+50 |
Storage temperature range (°C)
|
-20...+70 | -20...+70 |
Temperature coefficient of the sensitivity (% F.S.*/10°C) | <± 0.07 | <± 0.07 |
Temperature coefficient of zero signal (% F.S.*/10°C) | <± 0.02 | <± 0.02 |
Power supply (-)
|
110...230 VAC / 18...24 VDC | 18...24 VDC |
Output tension (V) | 0...10 / -10...0...+10 (load R. >= 5 kohms) | 0...10 / -10...0...+10 (load R. >= 5 kohms) |
Output current (mA) | 0...20 / 4...20 (load R.<= 500 ohms) | 0...20 / 4...20 (load R.<= 500 ohms) |
IP rating (-)
|
IP67 | IP67 |
* F.S. : Full Scale.
** : except thermal drifts.
Specifications subject to change without notice.
Associated electronics
EOT cranes recording and managing electronics. |
Conditionner-amplifier with 4..20 mA and 0..10 V output. |
Crane overload protection electronics with 3 set-points and display on a front panel. |
Conditioner-amplifier with 4..20 mA and -10..0..10 V output. |
Crane overload protection electronics with 3 set-points and display for hoisting device (EOT cranes,..). |
Two channels crane overload protection electronics. |
EOT crane overload protection electronics for hoisting device (EOT cranes, ...) |
High-accuracy digital indicator for standard reference force transducer. |
Very high accuracy digital indicator designed for weighing applications. |
Smart junction box designed for parallel connecting of 2 to 4 load cells to an electronics and to ensure the monitoring of their correct functioning. |
4 channels digital indicator for 3115F-12390. |
Hand-held indicator for transducer with mV/V output. |
Junction boxes designed to connect several load cells in parallel to the same electronics with corner adjustment. |
Analogue voltage and current signal converter with galvanic isolation. |
Very high-accuracy digital indicator for standard reference force transducer. |
Crane overload protection electronics for the sum of several load cells / load pins |
Crane overload protection electronics for 2 channels and their sum |
Crane overload protection electronics for 4 channels and their sum |
Overload protection electronics for hoisting devices with certification for performance level PL d according to EN ISO 13849-1. |
Converts the signal from a Wheatstone bridge (mV/V) into a standardised digital signal RS-232, RS-485 or USB. |
Radio transmitter for analogue signals (mV/V, 4..20 mA, 0..10 V). |
Radio receiver with analogue output (4..20 mA, 0..10 V). |
Base stations designed to connect wireless load cell (WI-T24TR-xxx) |
Base station designed to connect up to 8 wireless load cells (WI-T24TR-xxx) |
Crane overload protection electronics with 3 set-points and display for hazardous area. |
Converts the signal from the Wheatstone bridge (mV/V) into a robust industrial standardised 4 to 20 mA signal. |
Convert the signal from a Wheatstone bridge (mV/V) into a standardised digital signal RS-232, RS-485 or USB. |
Universal large panel meters to be used with transducers and process signals. |
Panel meters with dual line display for Wheatstone bridge sensors |
Universal panel meters for using with load cells and process signals. |
Crane overload protection electronics with 3 set-points and display on a front panel. |
Crane overload protection electronics for the sum of several load cells / load pins |
Crane overload protection electronics with 3 set-points and display for hoisting device (EOT cranes,...). |