CRANE OVERLOAD PROTECTION ELECTRONICS FOR THE SUM OF SEVERAL CHANNELS

CRANE-SUMD DISP-SUMD
CRANE-SUMD and DISP-SUMD are designed to limit the sum of the load of several hoisting devices already equipped with their own load limitation device.
o Type:
- CRANE-SUMD: with industrial metallic housing
- DISP-SUMD: to be installed on the front panel
o Connected to the analogue output (4...20 mA) of the load limitation electronics BRIDGE-BOY, CRANE-BOY, INDI-BOY, DISP-BOYP, etc. (CARD-CDL10 option)
o Easy and intuitive calibration
o Display of hoisted load and input signal
AVAILABLE OPTIONS
- analogue output 4(0)...20 mA / 0...10 V
- RS-232, RS-485 or fieldbus output
- power supply: 48 VAC / 24 VDC (see CRANE-SUMD2 and DISP-SUMD2 porducts)
- stainless steel housing
- NEMA 4X / IP67 (transparent protection cover - Option "COVER PAX")
- rail DIN adaptor
CRANE-SUMD | CRANE-SUMD12 | DISP-SUMD | DISP-SUMD12 | |
---|---|---|---|---|
Type (-) | Load limiter of the sum | Load limiter of the sum | Load limiter of the sum | Load limiter of the sum |
Input range (-)
|
±20 mA, ±200 mA | ±20 mA, ±200 mA | ±20 mA, ±200 mA | ±20 mA, ±200 mA |
Display (-) | 5 digits (14.2 mm) | 5 digits (14.2 mm) | 5 digits (14.2 mm) | 5 digits (14.2 mm) |
Accuracy (% F.S.*)
|
0.1 | 0.1 | 0.1 | 0.1 |
Service temperature range (°C)
|
0...+50 | 0...+50 | 0...+50 | 0...+50 |
Storage temperature range (°C)
|
-40...+60 | -40...+60 | -40...+60 | -40...+60 |
Power supply (-)
|
85...250 VAC, 50/60 Hz (15 VA) | 11...36 VDC (11 W) 24 VAC (15 VA) | 85...250 VAC, 50/60 Hz (15 VA) | 11...36 VDC (11 W) 24 VAC (15 VA) |
Qty of relay (-) | 3 | 3 | 3 | 3 |
Relay type (-) | "Form A"- potential free | Form A - potential free | Form A - potential free | Form A - potential free |
Contact rating (-) | 3 A @ 250 VAC / 30 VDC Resistive load | 3 A @ 250 VAC / 30 VDC Resistive load | 3 A @ 250 VAC or 30 VDC resistive load | 3 A @ 250 VAC or 30 VDC Resistive load |
IP rating (-)
|
IP54 | IP54 | IP54 | IP54 |
* F.S. : Full Scale.
** : except thermal drifts.
Specifications subject to change without notice.
Associated electronics
EOT cranes recording and managing electronics. |
Conditionner-amplifier with 4..20 mA and 0..10 V output. |
Crane overload protection electronics with 3 set-points and display on a front panel. |
Conditioner-amplifier with 4..20 mA and -10..0..10 V output. |
Crane overload protection electronics with 3 set-points and display for hoisting device (EOT cranes,..). |
Two channels crane overload protection electronics. |
EOT crane overload protection electronics for hoisting device (EOT cranes, ...) |
High-accuracy digital indicator for standard reference force transducer. |
Very high accuracy digital indicator designed for weighing applications. |
Smart junction box designed for parallel connecting of 2 to 4 load cells to an electronics and to ensure the monitoring of their correct functioning. |
4 channels digital indicator for 3115F-12390. |
Hand-held indicator for transducer with mV/V output. |
Junction boxes designed to connect several load cells in parallel to the same electronics with corner adjustment. |
Analogue voltage and current signal converter with galvanic isolation. |
Very high-accuracy digital indicator for standard reference force transducer. |
Crane overload protection electronics for the sum of several load cells / load pins |
Crane overload protection electronics for 2 channels and their sum |
Crane overload protection electronics for 4 channels and their sum |
Overload protection electronics for hoisting devices with certification for performance level PL d according to EN ISO 13849-1. |
Converts the signal from a Wheatstone bridge (mV/V) into a standardised digital signal RS-232, RS-485 or USB. |
Radio transmitter for analogue signals (mV/V, 4..20 mA, 0..10 V). |
Radio receiver with analogue output (4..20 mA, 0..10 V). |
Base stations designed to connect wireless load cell (WI-T24TR-xxx) |
Base station designed to connect up to 8 wireless load cells (WI-T24TR-xxx) |
Crane overload protection electronics with 3 set-points and display for hazardous area. |
Converts the signal from the Wheatstone bridge (mV/V) into a robust industrial standardised 4 to 20 mA signal. |
Convert the signal from a Wheatstone bridge (mV/V) into a standardised digital signal RS-232, RS-485 or USB. |
Universal large panel meters to be used with transducers and process signals. |
Panel meters with dual line display for Wheatstone bridge sensors |
Universal panel meters for using with load cells and process signals. |
Crane overload protection electronics with 3 set-points and display on a front panel. |
Crane overload protection electronics for the sum of several load cells / load pins |
Crane overload protection electronics with 3 set-points and display for hoisting device (EOT cranes,...). |