EOT CRANE OVERLOAD PROTECTION ELECTRONICS WITH 1 OR 3 SET-POINTS
BRIDGE-BOY
o Low cost
o 1 or 3 independent set-points
o Set-points 1 and 2 configurated for load limitation
o Set-point 3 configurated by default for slack cable detection
o Adjustments by potentiometers
o Analogue outputs: 0...10 V and 4...20 mA
o Din rail mounting (TS 35)
o 115 VAC available by internal jumper
BB-48VAC-1R | BB-230VAC-1R | BB-48VAC-3R | BB-230VAC-3R | |
---|---|---|---|---|
Type (-) | Load limiter with single strain-gauge input | Load limiter with single strain-gauge input | Load limiter with single strain-gauge input | Load limiter with single strain-gauge input |
Input range (-)
|
0.4...2 mV/V | 0.4...2 mV/V | 0.4...2 mV/V | 0.4...2 mV/V |
Sensor excitation (-) | 10...28 mA (11 V max) | 10...28 mA (11 V max) | 10...28 mA (11 V max) | 10...28 mA (11 V max) |
Accuracy (% F.S.*)
|
± 0.5 | ± 0.5 | ± 0.5 | ± 0.5 |
Service temperature range (°C)
|
-20...+60 | -20...+60 | -20...+60 | -20...+60 |
Storage temperature range (°C)
|
-40...+70 | -40...+70 | -40...+70 | -40...+70 |
Power supply (-)
|
48-110 VAC (50 / 60 Hz, 4 VA) | 115-230 VAC (50 / 60 Hz, 3 VA) | 48-110 VAC (50 / 60 Hz, 4 VA) | 115-230 VAC (50 / 60 Hz, 3 VA) |
Qty of relay (-) | 1 | 1 | 3 | 3 |
Relay type (-) | "Form C" activated in safe situation | "Form C" activated in safe situation | "Form C" activated in safe situation | "Form C" activated in safe situation |
Contact rating (-) | 6 A @ 250 VAC | 6 A @ 250 VAC | 6 A @ 250 VAC | 6 A @ 250 VAC |
Adjustable delay (-) | 60 ms...1 s | 60 ms...1 s | 60 ms...1 s | 60 ms...1 s |
Output tension (V) | 0..10 (load resistance >= 2.5 kohms) | 0..10 (load resistance >= 2.5 kohms) | 0..10 (load resistance >= 2.5 kohms) | 0..10 (load resistance >= 2.5 kohms) |
Output current (mA) | 4...20 mA (load resistance <= 500 ohms) | 4...20 mA (load resistance <= 500 ohms) | 4...20 mA (load resistance <= 500 ohms) | 4...20 mA (load resistance <= 500 ohms) |
IP rating (-)
|
IP20 | IP20 | IP20 | IP20 |
* F.S. : Full Scale.
** : except thermal drifts.
Specifications subject to change without notice.
- MA-BRIDGEBOY_EN.pdf (567.44k)
- MA-BRIDGEBOY_FR.pdf (579.07k)
- MA-BRIDGEBOY SOM_EN.pdf (413.50k)
- MA-BRIDGEBOY SOM_FR.pdf (413.01k)
Associated electronics
EOT cranes recording and managing electronics. |
Conditionner-amplifier with 4..20 mA and 0..10 V output. |
Crane overload protection electronics with 3 set-points and display on a front panel. |
Conditioner-amplifier with 4..20 mA and -10..0..10 V output. |
Crane overload protection electronics with 3 set-points and display for hoisting device (EOT cranes,..). |
Two channels crane overload protection electronics. |
EOT crane overload protection electronics for hoisting device (EOT cranes, ...) |
High-accuracy digital indicator for standard reference force transducer. |
Very high accuracy digital indicator designed for weighing applications. |
Smart junction box designed for parallel connecting of 2 to 4 load cells to an electronics and to ensure the monitoring of their correct functioning. |
4 channels digital indicator for 3115F-12390. |
Hand-held indicator for transducer with mV/V output. |
Junction boxes designed to connect several load cells in parallel to the same electronics with corner adjustment. |
Analogue voltage and current signal converter with galvanic isolation. |
Very high-accuracy digital indicator for standard reference force transducer. |
Crane overload protection electronics for the sum of several load cells / load pins |
Crane overload protection electronics for 2 channels and their sum |
Crane overload protection electronics for 4 channels and their sum |
Overload protection electronics for hoisting devices with certification for performance level PL d according to EN ISO 13849-1. |
Converts the signal from a Wheatstone bridge (mV/V) into a standardised digital signal RS-232, RS-485 or USB. |
Radio transmitter for analogue signals (mV/V, 4..20 mA, 0..10 V). |
Radio receiver with analogue output (4..20 mA, 0..10 V). |
Base stations designed to connect wireless load cell (WI-T24TR-xxx) |
Base station designed to connect up to 8 wireless load cells (WI-T24TR-xxx) |
Crane overload protection electronics with 3 set-points and display for hazardous area. |
Converts the signal from the Wheatstone bridge (mV/V) into a robust industrial standardised 4 to 20 mA signal. |
Convert the signal from a Wheatstone bridge (mV/V) into a standardised digital signal RS-232, RS-485 or USB. |
Universal large panel meters to be used with transducers and process signals. |
Panel meters with dual line display for Wheatstone bridge sensors |
Universal panel meters for using with load cells and process signals. |
Crane overload protection electronics with 3 set-points and display on a front panel. |
Crane overload protection electronics for the sum of several load cells / load pins |
Crane overload protection electronics with 3 set-points and display for hoisting device (EOT cranes,...). |