SMART JUNCTION BOX MONITORING LOAD CELL INTEGRITY
JBOX-LCI
o Control of:
- load cell out of pre-set balance range
- load cell out of pre-set operating range
- low / high excitation
- open circuit to any load cell on each connection
- short circuit on any load cell connection
- internal load cell fault (bridge imbalance)
o Ensure the positive safety of load limitation systems based on multiple load cells connected in parallel (hoisting devices)
AVAILABLE OPTIONS
- ABS housing available with DIN rail mounting accessories- PCB available without ABS housing
JBOX-LCI | |
---|---|
Type (-) | Smart junction box |
Input range (-)
|
1...5 mV/V |
Sensor excitation (-) | 4...12 VDC () |
Non-linearity error (% F.S.*)
|
<± 0.03 |
Display (-) | 4 digits |
Service temperature range (°C)
|
-10...+85 |
Storage temperature range (°C)
|
-40...+95 |
Temperature coefficient of the sensitivity (% F.S.*/10°C) | <± 0.02 |
Temperature coefficient of zero signal (% F.S.*/10°C) | <± 0.2 |
Power supply (-)
|
4...12 VDC |
Qty of relay (-) | 1 |
Relay type (-) | SPCO relay |
Contact rating (-) | 0.5 A (50 VDC max.) / 1 A (24 VDC / 120 VAC) |
IP rating (-)
|
IP65 |
* F.S. : Full Scale.
** : except thermal drifts.
Specifications subject to change without notice.
Associated electronics
EOT cranes recording and managing electronics. |
Conditionner-amplifier with 4..20 mA and 0..10 V output. |
Crane overload protection electronics with 3 set-points and display on a front panel. |
Conditioner-amplifier with 4..20 mA and -10..0..10 V output. |
Crane overload protection electronics with 3 set-points and display for hoisting device (EOT cranes,..). |
Two channels crane overload protection electronics. |
EOT crane overload protection electronics for hoisting device (EOT cranes, ...) |
High-accuracy digital indicator for standard reference force transducer. |
Very high accuracy digital indicator designed for weighing applications. |
Smart junction box designed for parallel connecting of 2 to 4 load cells to an electronics and to ensure the monitoring of their correct functioning. |
4 channels digital indicator for 3115F-12390. |
Hand-held indicator for transducer with mV/V output. |
Junction boxes designed to connect several load cells in parallel to the same electronics with corner adjustment. |
Analogue voltage and current signal converter with galvanic isolation. |
Very high-accuracy digital indicator for standard reference force transducer. |
Crane overload protection electronics for the sum of several load cells / load pins |
Crane overload protection electronics for 2 channels and their sum |
Crane overload protection electronics for 4 channels and their sum |
Overload protection electronics for hoisting devices with certification for performance level PL d according to EN ISO 13849-1. |
Converts the signal from a Wheatstone bridge (mV/V) into a standardised digital signal RS-232, RS-485 or USB. |
Radio transmitter for analogue signals (mV/V, 4..20 mA, 0..10 V). |
Radio receiver with analogue output (4..20 mA, 0..10 V). |
Base stations designed to connect wireless load cell (WI-T24TR-xxx) |
Base station designed to connect up to 8 wireless load cells (WI-T24TR-xxx) |
Crane overload protection electronics with 3 set-points and display for hazardous area. |
Converts the signal from the Wheatstone bridge (mV/V) into a robust industrial standardised 4 to 20 mA signal. |
Convert the signal from a Wheatstone bridge (mV/V) into a standardised digital signal RS-232, RS-485 or USB. |
Universal large panel meters to be used with transducers and process signals. |
Panel meters with dual line display for Wheatstone bridge sensors |
Universal panel meters for using with load cells and process signals. |
Crane overload protection electronics with 3 set-points and display on a front panel. |
Crane overload protection electronics for the sum of several load cells / load pins |
Crane overload protection electronics with 3 set-points and display for hoisting device (EOT cranes,...). |