STRAIN-GAUGE EMBEDDED DIGITAL CONVERTERS
DIGITAL CONVERTERS
o Very high resolution
o Linearisation of transducer signal available
o High transmission speed
o Internal or external mounting depending on the size of the transducer
o When external, rectangular box in aluminium (protection class IP65)
AVAILABLE OPTIONS
- temperature measurement with compensation of thermal drifts| RS232-ASC | RS485-ASC | RS485-MOD | USB-ASC | |
|---|---|---|---|---|
|
Input range (-)
|
± 3 mV/V | ± 3 mV/V | ± 3 mV/V | 3 mV/V |
| Sensor excitation (-) | 4.5...5.25 VDC | 4.5...5.25 VDC | 4.5...5.25 VDC | 5 VDC |
|
Non-linearity error (% F.S.*)
|
<=± 0.003 | <=± 0.003 | <=± 0.003 | 0.0025 |
| Impedance of Wheatstone bridge (ohm(s)) | 320...5000 | 320...5000 | 320...5000 | 85...5000 |
| Baud rate (-) | 2.4...230 kbps | 2.4...230 kbps | 2.4...230 kbps | 115...200 kbps |
|
A/D converter (-)
|
5000...66 000 div. | 5000...66 000 div. | 5000...66 000 div. | 50 000...200 000 div. |
| Protocol (-) | ASCII | ASCII | MODBUS | ASCII |
|
Bandwidth (Hz)
|
1...500 | 1...500 | 1...500 | 1...100 |
|
Service temperature range (°C)
|
-40...+85 | -40...+85 | -40...+85 | -40...+85 |
| Temperature coefficient of the sensitivity (% F.S.*/10°C) | <± 0.05 | <± 0.05 | <± 0.05 | 0.005 |
| Temperature coefficient of zero signal (% F.S.*/10°C) | <± 0.01 | <± 0.01 | <± 0.01 | 0.004 |
|
Power supply (-)
|
5.6...12...18 VDC | 5.6...12...18 VDC | 5.6...12...18 VDC | USB |
| Consumption (max.) (mA) | 60 | 60 | 60 | 68 |
* F.S. : Full Scale.
** : except thermal drifts.
Specifications subject to change without notice.
Associated electronics
EOT cranes recording and managing electronics. |
Conditionner-amplifier with 4..20 mA and 0..10 V output. |
| Crane overload protection electronics with 3 set-points and display on a front panel. |
| Conditioner-amplifier with 4..20 mA and -10..0..10 V output. |
| Crane overload protection electronics with 3 set-points and display for hoisting device (EOT cranes,..). |
| Two channels crane overload protection electronics. |
| EOT crane overload protection electronics for hoisting device (EOT cranes, ...) |
| High-accuracy digital indicator for standard reference force transducer. |
| Very high accuracy digital indicator designed for weighing applications. |
| Smart junction box designed for parallel connecting of 2 to 4 load cells to an electronics and to ensure the monitoring of their correct functioning. |
| 4 channels digital indicator for 3115F-12390. |
| Hand-held indicator for transducer with mV/V output. |
| Junction boxes designed to connect several load cells in parallel to the same electronics with corner adjustment. |
| Analogue voltage and current signal converter with galvanic isolation. |
| Very high-accuracy digital indicator for standard reference force transducer. |
Crane overload protection electronics for the sum of several load cells / load pins |
| Crane overload protection electronics for 2 channels and their sum |
Crane overload protection electronics for 4 channels and their sum |
| Overload protection electronics for hoisting devices with certification for performance level PL d according to EN ISO 13849-1. |
| Converts the signal from a Wheatstone bridge (mV/V) into a standardised digital signal RS-232, RS-485 or USB. |
| Radio transmitter for analogue signals (mV/V, 4..20 mA, 0..10 V). |
| Radio receiver with analogue output (4..20 mA, 0..10 V). |
| Base stations designed to connect wireless load cell (WI-T24TR-xxx) |
| Base station designed to connect up to 8 wireless load cells (WI-T24TR-xxx) |
Crane overload protection electronics with 3 set-points and display for hazardous area. |
| Converts the signal from the Wheatstone bridge (mV/V) into a robust industrial standardised 4 to 20 mA signal. |
| Convert the signal from a Wheatstone bridge (mV/V) into a standardised digital signal RS-232, RS-485 or USB. |
Universal large panel meters to be used with transducers and process signals. |
Panel meters with dual line display for Wheatstone bridge sensors |
Universal panel meters for using with load cells and process signals. |
Crane overload protection electronics with 3 set-points and display on a front panel. |
Crane overload protection electronics for the sum of several load cells / load pins |
Crane overload protection electronics with 3 set-points and display for hoisting device (EOT cranes,...). |