THROUGH HOLE (ANNULAR) HEAVY-CAPACITY LOAD CELLS
5190-5195
SL | |
---|---|
Repeatability error (% F.S.*) | <± 0.25 |
Creep error over 30 min. (% F.S.*)
|
<± 0.3 |
Zero shift after loading (% F.S.*)
|
<± 0.5 |
Reference temperature (°C) | 23 |
Compensated temperature range (°C) | -10...+45 |
Service temperature range (°C)
|
-30...+70 |
Storage temperature range (°C)
|
-50...+85 |
Temperature coefficient of the sensitivity (% F.S.*/10°C) | <± 0.2 |
Temperature coefficient of zero signal (% F.S.*/10°C) | <± 0.2 |
Zero balance (mV/V)
|
± 0.02 |
Nominal sensitivity (mV/V)
|
1.5 |
Input resistance (ohm(s)) | 700 ± 2 |
Output resistance (ohm(s)) | 700 ± 2 |
Insulation resistance (50 V) (Mohm(s)) | > 5000 |
Reference excitation voltage (VDC)
|
10 |
Permissible nominal range of excitation voltage (VDC) | 3...12 |
Safe load limit (% F.S.*) | 150 |
Breaking load (% F.S.*)
|
> 300 |
Permissible dynamic loading (% F.S.*)
|
50 |
Static lateral force limit (% F.S.*)
|
25 |
* F.S. : Full Scale.
** : except thermal drifts.
Specifications subject to change without notice.
Datasheets
Manuals
Support
Typical applications