REACTION TORQUE METERS


ATEX CE

6200-6205

Universal non-rotating torque meters combining accuracy and sturdiness.

- Easy to install, compact design
- Protection class: see drawing table (IP)
- Materials: stainless steel (6200), nickel-plated steel (6205)
- Cable length: 3 m (other lengths available on request)
- Also available as standard reference torque meters


AVAILABLE OPTIONS

AMPLIFIED-OUTPUT
DIGITAL-OUTPUT
EXi
-50+180
Get our
Standard Item
Do you have
specific need ?
Add to basket
for quotation


Drop your files here
0.25 %
Repeatability error (% F.S.*) <± 0.1
Creep error over 30 min. (% F.S.*)
<± 0.1
Zero shift after loading (% F.S.*)
<± 0.025
Reference temperature (°C) 23
Compensated temperature range (°C) -10...+45
Service temperature range (°C)
-30...+70
Storage temperature range (°C)
-50...+85
Temperature coefficient of the sensitivity (% F.S.*/10°C) <± 0.05
Temperature coefficient of zero signal (% F.S.*/10°C) <± 0.035
Zero balance (mV/V)
± 0.02
Nominal sensitivity (mV/V)
1.5
Sensitivity tolerance (%) <± 0.3
Input resistance (ohm(s)) 350 ± 2
Output resistance (ohm(s)) 350 ± 2
Insulation resistance (50 V) (Mohm(s)) > 5000
Reference excitation voltage (VDC)
10
Permissible nominal range of excitation voltage (VDC) 3...12
Safe load limit (% F.S.*) 130
Breaking load (% F.S.*)
>300
Permissible dynamic loading (% F.S.*)
50

* F.S. : Full Scale.
** : except thermal drifts.
Specifications subject to change without notice.

Typical applications
Download our leaflet

Associated electronics