INSERTABLE STRAIN SENSOR - INSERTGAGE®
3300
Insertable extensometer designed to measure the force in a structure
o Designed to measure:
- tension, compression shear and bending force
- torque
o One unique model regardless of the capacity range
o Material: stainless steel
o Protection class: IP67
o Very competitive prices
o Easy to install (one hole to drill)
o Accuracy in the structure: 2 to 5 %
o Cable length: 0.25 or 5 m (other lengths available on request)
| 2 - 5 % | |
|---|---|
| Reference temperature (°C) | 23 |
| Compensated temperature range (°C) | -10...+45 |
|
Service temperature range (°C)
|
-30...+60 |
|
Storage temperature range (°C)
|
-50...+85 |
|
Nominal sensitivity (mV/V)
|
± 1 |
| Input resistance (ohm(s)) | 700 ± 2 |
| Output resistance (ohm(s)) | 700 ± 2 |
| Insulation resistance (50 V) (Mohm(s)) | > 5000 |
|
Reference excitation voltage (VDC)
|
10 |
| Permissible nominal range of excitation voltage (VDC) | 3...12 |
* F.S. : Full Scale.
** : except thermal drifts.
Specifications subject to change without notice.
Datasheets
Manuals
Associated electronics
Conditionner-amplifier with 4..20 mA and 0..10 V output. |
| Conditioner-amplifier with 4..20 mA and -10..0..10 V output. |
| Very high accuracy digital indicator designed for weighing applications. |
| Smart junction box designed for parallel connecting of 2 to 4 load cells to an electronics and to ensure the monitoring of their correct functioning. |
| Hand-held indicator for transducer with mV/V output. |
| Junction boxes designed to connect several load cells in parallel to the same electronics with corner adjustment. |
| Analogue voltage and current signal converter with galvanic isolation. |
| Converts the signal from a Wheatstone bridge (mV/V) into a standardised digital signal RS-232, RS-485 or USB. |
| Radio transmitter for analogue signals (mV/V, 4..20 mA, 0..10 V). |
| Radio receiver with analogue output (4..20 mA, 0..10 V). |
| Base stations designed to connect wireless load cell (WI-T24TR-xxx) |
| Base station designed to connect up to 8 wireless load cells (WI-T24TR-xxx) |
| Converts the signal from the Wheatstone bridge (mV/V) into a robust industrial standardised 4 to 20 mA signal. |
| Convert the signal from a Wheatstone bridge (mV/V) into a standardised digital signal RS-232, RS-485 or USB. |
Universal large panel meters to be used with transducers and process signals. |
Panel meters with dual line display for Wheatstone bridge sensors |
Universal panel meters for using with load cells and process signals. |