LOW-PROFILE COMPRESSION LOAD CELLS
5950
Load cells combining high capacity, low design and cost-effective solution.
o Material: stainless steel
o Protection class: IP67
o Low design
o Cost-effective solution
o Sturdy design
o Easy to install
o Whole range of mounting kits available
o Cable length: 8 m (other lengths available on request)
0.5 % | 0.25 % | 0.1 % | |
---|---|---|---|
Accuracy class (-)
|
0.5 % F.S. | 0.25 % F.S. | 0.1% F.S. |
Combined error (non-linearity + hysteresis) (% F.S.*) | < ± 0.5 | <± 0.25 | < ± 0.1 |
Repeatability error (% F.S.*) | < ± 0.25 | <± 0.1 | <± 0.03 |
Creep error over 30 min. (% F.S.*)
|
< ± 0.2 | <± 0.1 | <± 0.06 |
Reference temperature (°C) | 23 | 23 | 23 |
Compensated temperature range (°C) | -10...+45 | -10...+45 | -10...+45 |
Service temperature range (°C)
|
-25...+70 | -25...+70 | -25...+70 |
Storage temperature range (°C)
|
-50...+85 | -50...+85 | -50...+85 |
Temperature coefficient of the sensitivity (% F.S.*/10°C) | < ± 0.1 | <± 0.05 | <± 0.05 |
Temperature coefficient of zero signal (% F.S.*/10°C) | < ± 0.1 | <± 0.035 | <± 0.035 |
Nominal sensitivity (mV/V)
|
1.5 | 1.5 | 1.5 |
Sensitivity tolerance (%) | < ± 0.5 | <± 0.3 | <± 0.3 |
Input resistance (ohm(s)) | 700 ± 2 | 700 ± 2 | 700 ± 2 |
Output resistance (ohm(s)) | 700 ± 2 | 700 ± 2 | 700 ± 2 |
Insulation resistance (50 V) (Mohm(s)) | > 5000 | > 5000 | > 5000 |
Reference excitation voltage (VDC)
|
10 | 10 | 10 |
Permissible nominal range of excitation voltage (VDC) | 3...12 | 3...12 | 3...12 |
Safe load limit (% F.S.*) | 150 | 150 | 150 |
Breaking load (% F.S.*)
|
>300 | >300 | >300 |
Permissible dynamic loading (% F.S.*)
|
40 | 40 | 40 |
Static lateral force limit (% F.S.*)
|
10 | 10 | 10 |
* F.S. : Full Scale.
** : except thermal drifts.
Specifications subject to change without notice.
Datasheets
Manuals
Support