SHEAR BEAM LOAD CELLS


4500
Load cells for silo weighing combining a sturdy design with easy installation.
o Material: stainless steel
o Protection class: IP67
o Easy to install, cost-effective solution, sturdy design
o Cable length: see drawing table - CL (other lengths available on request)
o Mounting kits available with following properties:
- stabilisation without tension rods
- anti-lift-off device
- compensation for thermal dilatations and defective alignment
0.1 % | |
---|---|
Accuracy class (-)
|
0.1% F.S. |
Combined error (non-linearity + hysteresis) (% F.S.*) | < ± 0.1 |
Repeatability error (% F.S.*) | <± 0.03 |
Creep error over 30 min. (% F.S.*)
|
<± 0.06 |
Reference temperature (°C) | 23 |
Compensated temperature range (°C) | -10...+45 |
Service temperature range (°C)
|
-25...+70 |
Storage temperature range (°C)
|
-50...+85 |
Temperature coefficient of the sensitivity (% F.S.*/10°C) | <± 0.05 |
Temperature coefficient of zero signal (% F.S.*/10°C) | <± 0.035 |
Nominal sensitivity (mV/V)
|
2 |
Sensitivity tolerance (%) | <± 0.3 |
Input resistance (ohm(s)) | 350 ± 2 |
Output resistance (ohm(s)) | 350 ± 2 |
Insulation resistance (50 V) (Mohm(s)) | > 5000 |
Reference excitation voltage (VDC)
|
10 |
Permissible nominal range of excitation voltage (VDC) | 3...12 |
Safe load limit (% F.S.*) | 150 |
Breaking load (% F.S.*)
|
>300 |
Permissible dynamic loading (% F.S.*)
|
50 |
Static lateral force limit (% F.S.*)
|
100 |
* F.S. : Full Scale.
** : except thermal drifts.
Specifications subject to change without notice.