SINGLE POINT LOAD CELLS "OFF CENTER"
2162L
Economical single point load cells specially designed for small platform and hopper weighing.
o Designed for off-center load
o Maximum platform size: 400 x 400 mm
o Material: anodised aluminium alloy
o Protection class: IP63
o Competitive price
o Easy to install
o Weight: 0.35 kg
o Cable length: 2 m (other lengths available on request)
| A3 | |
|---|---|
|
Accuracy class (-)
|
0.03 % F.S. |
| Combined error (non-linearity + hysteresis) (% F.S.*) | <± 0.03 |
| Repeatability error (% F.S.*) | <± 0.015 |
|
Creep error over 30 min. (% F.S.*)
|
<± 0.03 |
| Reference temperature (°C) | 23 |
| Compensated temperature range (°C) | -10...+45 |
|
Service temperature range (°C)
|
-30...+70 |
|
Storage temperature range (°C)
|
-50...+85 |
| Temperature coefficient of the sensitivity (% F.S.*/10°C) | < ± 0.1 |
| Temperature coefficient of zero signal (% F.S.*/10°C) | < ± 0.05 |
|
Zero balance (mV/V)
|
± 0.02 |
|
Nominal sensitivity (mV/V)
|
2 ± 10% |
| Sensitivity tolerance (%) | <± 0.2 |
| Input resistance (ohm(s)) | 350 ± 2 |
| Output resistance (ohm(s)) | 350 ± 2 |
| Insulation resistance (50 V) (Mohm(s)) | > 5000 |
|
Reference excitation voltage (VDC)
|
10 |
| Permissible nominal range of excitation voltage (VDC) | 3..12 |
| Safe load limit (% F.S.*) | 150 |
|
Breaking load (% F.S.*)
|
>300 |
|
Permissible dynamic loading (% F.S.*)
|
60 |
|
Static lateral force limit (% F.S.*)
|
100 |
* F.S. : Full Scale.
** : except thermal drifts.
Specifications subject to change without notice.
Datasheets
Manuals
Support
Typical applications