SUBSEA / SUBMERGED LOAD PINS


ATEX CE LEVAGE OVERLOAD

5050

Design for underwater applications.

o Custom-made dimensioning
o Sturdy design
o Material: stainless steel
o Protection class: IP68
o Easy to install
o Depth: up to -7500 m / -24 606 ft (750 bars / 11 000 psi)  - deeper on request
o Cable length: 6 m (other lengths available on request)



custom subsea load-pin configurator 5050 CONFIGURATOR SUBSEA LOAD PIN 5050

AVAILABLE OPTIONS

DUAL-BRIDGE
SIL-PL
AMPLIFIED-OUTPUT
MULTI-AXIS
EXd
EXi
-50+180
SUBMERGED-CONNECTOR
Get our
Standard Item
Do you have
specific need ?
Add to basket
for quotation


Drop your files here
SL - FORCE SL - HOIST
Combined error (non-linearity + hysteresis) (% F.S.*) 0.25 - 1 0.5 - 2
Repeatability error (% F.S.*) <± 0.25 <± 0.25
Creep error over 30 min. (% F.S.*)
<± 0.3 <± 0.3
Zero shift after loading (% F.S.*)
<± 0.5 <± 0.5
Reference temperature (°C) 23 23
Compensated temperature range (°C) -10...+45 -10...+45
Service temperature range (°C)
-25...+70 -25...+70
Storage temperature range (°C)
-50...+85 -50...+85
Temperature coefficient of the sensitivity (% F.S.*/10°C) <± 0.2 <± 0.2
Temperature coefficient of zero signal (% F.S.*/10°C) <± 0.2 <± 0.2
Zero balance (mV/V)
± 0.02 ± 0.02
Nominal sensitivity (mV/V)
± 1.5 ± 1
Input resistance (ohm(s)) 350 ± 2 350 ± 2
Output resistance (ohm(s)) 350 ± 2 350 ± 2
Insulation resistance (50 V) (Mohm(s)) > 5000 > 5000
Reference excitation voltage (VDC)
10 10
Permissible nominal range of excitation voltage (VDC) 3...12 3...12
Safe load limit (% F.S.*) 150 200
Breaking load (% F.S.*)
> 300 > 500
Permissible dynamic loading (% F.S.*)
50 75
Static lateral force limit (% F.S.*)
100 150

* F.S. : Full Scale.
** : except thermal drifts.
Specifications subject to change without notice.