STATIC LINE TENSIOMETERS


ATEX CE CSA IECEX

5560S-5562S

Load cells specially designed to measure the tension force applied to a static wire rope or rope fiber.

o Easy and fast mounting
o Protection class: IP67
o Wide range of cable diameters: from 3 up to 90 mm (0.11 to 3.5")
o Material:
    - stainless steel (5560S)
   - anodised aluminium alloy (5562S)
o Cable length: 6 m (other lengths available on request)



tensiometer configurator 5560SCONFIGURATOR STATIC LINE TENSIOMETER5560S

AVAILABLE OPTIONS

DUAL-BRIDGE
AMPLIFIED-OUTPUT
DIGITAL-OUTPUT
WIRELESS
EXi
-50+150
IP68
SUBMERGED-CONNECTOR
Get our
Standard Item
Do you have
specific need ?
Add to basket
for quotation


Drop your files here
2 - 5 %
Reference temperature (°C) 23
Compensated temperature range (°C) -10...+45
Service temperature range (°C)
-30...+70
Storage temperature range (°C)
-50...+85
Temperature coefficient of the sensitivity (% F.S.*/10°C) <± 0.1
Temperature coefficient of zero signal (% F.S.*/10°C) <± 0.1
Nominal sensitivity (mV/V)
± 1
Input resistance (ohm(s)) 350 ± 2
Output resistance (ohm(s)) 350 ± 2
Insulation resistance (50 V) (Mohm(s)) > 5000
Reference excitation voltage (VDC)
10
Permissible nominal range of excitation voltage (VDC) 3...12
Safe load limit (% F.S.*) 200
Breaking load (% F.S.*)
>300
Permissible dynamic loading (% F.S.*)
70

* F.S. : Full Scale.
** : except thermal drifts.
Specifications subject to change without notice.

Typical applications
Download our leaflet

Associated electronics