Load cells often used for this type of application
2960-2962-2965
LOW-PROFILE (PANCAKE) LOAD CELLS
Universal tension and compression load cells for industrial force measurement.<br /><body text="#000000" bgcolor="#ffffff"><p>o Flat design<br>o High stiffness and fatigue resistant<br>o Highly resistant to transverse forces<br>o Protection class: IP66<br>o Complete range of mounting accessories available <br>o Material: stainless steel (2960)**, anodised aluminium alloy (2962), alloy steel (2965)<br>o Cable length: see drawing table - CL (other lengths available on request)</p></body><div style="padding-top: 20px; margin-bottom: -30px"><p style="font-weight: bold;margin-bottom: 12px;color: #389be1;">AVAILABLE OPTIONS</p><div style="display: inline-block; margin-right: 2px" data-toggle="tooltip" data-original-title="Two independent Wheatstone bridges equipped with strain gauges"><a class="options" href="/en/load-cells-options/dual-bridge-load-cells-option "><img src="//files.sensy.com/Illustration Options/EN/DUAL-BRIDGE-LOAD-CELLS-OPTION.svg" width="60" height= "60" border="0" alt="DUAL-BRIDGE" /></a></div><div style="display: inline-block; margin-right: 2px" data-toggle="tooltip" data-original-title="Safety Integrity Levels (EN 62061 standard) or PL (Performance Levels - ISO 13849 standard)"><a class="options" href="/en/load-cells-options/sil-load-pins-load-cells-safety-integrity-levels-option "><img src="//files.sensy.com/Illustration Options/EN/SIL-PL-READY-LOAD-PINS-LOAD-CELLS-OPTION.svg" width="60" height= "60" border="0" alt="SIL-PL" /></a></div><div style="display: inline-block; margin-right: 2px" data-toggle="tooltip" data-original-title="see : Analogue amplifiers"><a class="options" href="/en/load-cells-options/load-cell-EMBEDDED-ANALOGUE-AMPLIFIER-option"><img src="//files.sensy.com/Illustration Options/EN/EMBEDDED-STRAIN-GAUGE-AND-LOAD-CELL-SIGNAL-CONDITIONER-AMPLIFIER-OPTION.svg" width="60" height= "60" border="0" alt="AMPLIFIED-OUTPUT" /></a></div><div style="display: inline-block; margin-right: 2px" data-toggle="tooltip" data-original-title="see : DIGITAL CONVERTERS"><a class="options" href="/en/load-cells-options/load-cell-EMBEDDED-DIGITAL-CONVERTER-option"><img src="//files.sensy.com/Illustration Options/EN/EMBEDDED-LOAD-CELL-AND-DIGITAL-STRAIN-GAUGE-CONVERTER-OPTION.svg" width="60" height= "60" border="0" alt="DIGITAL-OUTPUT" /></a></div><div style="display: inline-block; margin-right: 2px" data-toggle="tooltip" data-original-title="see : COND-USB"><a class="options" href="/en/load-cells-options/usb-load-cell-strain-gauge-to-usb-converter-option "><img src="//files.sensy.com/Illustration Options/EN/USB-LOAD-CELL-STRAIN-GAUGE-TO-USB-CONVERTER-OPTION.svg" width="60" height= "60" border="0" alt="USB" /></a></div><div style="display: inline-block; margin-right: 2px" data-toggle="tooltip" data-original-title="Wireless"><a class="options" href="/en/load-cells-options/wireless-load-pins-load-shackles-load-cells-option "><img src="//files.sensy.com/Illustration Options/EN/WIRELESS-LOAD-PINS-LOAD-SHACKLES-LOAD-CELLS-OPTION.svg" width="60" height= "60" border="0" alt="WIRELESS" /></a></div><div style="display: inline-block; margin-right: 2px" data-toggle="tooltip" data-original-title="Operating or compensated temperature (to be define)"><a class="options" href="/en/load-cells-options/low-temperature-load-pins-50-180-option "><img src="//files.sensy.com/Illustration Options/EN/LOW-TEMPERATURE-LOAD-PINS-50-180-OPTION.svg" width="60" height= "60" border="0" alt="-50+180" /></a></div><div style="display: inline-block; margin-right: 2px" data-toggle="tooltip" data-original-title="Based on the limitation of electrical energy provided to an equipment"><a class="options" href="/en/load-cells-options/atex-iecex-csa-intrinsically-safe-load-cells "><img src="//files.sensy.com/Illustration Options/EN/ATEX-IECEX-CSA-INTRINSICALLY-SAFE-LOAD-CELLS-OPTION.svg" width="60" height= "60" border="0" alt="EXi" /></a></div><div style="display: inline-block; margin-right: 2px" data-toggle="tooltip" data-original-title="Multi-direction measurements (forces and moments)"><a class="options" href="/en/load-cells-options/multiple-force-load-pins-multiple-moments-load-cells-option "><img src="//files.sensy.com/Illustration Options/EN/MULTIPLE-FORCE-LOAD-PINS-MULTIPLE-MOMENTS-LOAD-CELLS-OPTION.svg" width="60" height= "60" border="0" alt="MULTIPLE-MOMENTS" /></a></div><div style="display: inline-block; margin-right: 2px" data-toggle="tooltip" data-original-title="Protection rating"><a class="options" href="/en/load-cells-options/subsea-load-pin-with-submerged-connector-option "><img src="//files.sensy.com/Illustration Options/EN/SUBSEA-LOAD-PINS-IP68-OPTION.svg" width="60" height= "60" border="0" alt="IP68" /></a></div></div> |
5190-5195
THROUGH HOLE (ANNULAR) HEAVY-CAPACITY LOAD CELLS
<p>Annular compression load cells.</p> <p>o Low profile for high-capacity load cells<br />o Material: stainless steel (5190) or nickel-plated steel (5195) <br />o Protection class: IP65<br />o Sturdy design<br />o Cable length: see drawing table - CL (other lengths available on request)</p> <p></p> <div style="padding-top: 20px; margin-bottom: -30px;"> <p style="font-weight: bold; margin-bottom: 12px; color: #389be1;">AVAILABLE OPTIONS</p> <div style="display: inline-block; margin-right: 2px;" data-toggle="tooltip" data-original-title="Two independent Wheatstone bridges equipped with strain gauges"><a class="options" href="/en/load-cells-options/dual-bridge-load-cells-option "><img src="//files.sensy.com/Illustration Options/EN/DUAL-BRIDGE-LOAD-CELLS-OPTION.svg" width="60" height="60" border="0" alt="DUAL-BRIDGE" /></a></div> <div style="display: inline-block; margin-right: 2px;" data-toggle="tooltip" data-original-title="see : Analogue amplifiers"><a class="options" href="/en/load-cells-options/load-cell-EMBEDDED-ANALOGUE-AMPLIFIER-option"><img src="//files.sensy.com/Illustration Options/EN/EMBEDDED-STRAIN-GAUGE-AND-LOAD-CELL-SIGNAL-CONDITIONER-AMPLIFIER-OPTION.svg" width="60" height="60" border="0" alt="AMPLIFIED-OUTPUT" /></a></div> <div style="display: inline-block; margin-right: 2px;" data-toggle="tooltip" data-original-title="see : DIGITAL CONVERTERS"><a class="options" href="/en/load-cells-options/load-cell-EMBEDDED-DIGITAL-CONVERTER-option"><img src="//files.sensy.com/Illustration Options/EN/EMBEDDED-LOAD-CELL-AND-DIGITAL-STRAIN-GAUGE-CONVERTER-OPTION.svg" width="60" height="60" border="0" alt="DIGITAL-OUTPUT" /></a></div> <div style="display: inline-block; margin-right: 2px;" data-toggle="tooltip" data-original-title="see : COND-USB"><a class="options" href="/en/load-cells-options/usb-load-cell-strain-gauge-to-usb-converter-option "><img src="//files.sensy.com/Illustration Options/EN/USB-LOAD-CELL-STRAIN-GAUGE-TO-USB-CONVERTER-OPTION.svg" width="60" height="60" border="0" alt="USB" /></a></div> <div style="display: inline-block; margin-right: 2px;" data-toggle="tooltip" data-original-title="Wireless"><a class="options" href="/en/load-cells-options/wireless-load-pins-load-shackles-load-cells-option "><img src="//files.sensy.com/Illustration Options/EN/WIRELESS-LOAD-PINS-LOAD-SHACKLES-LOAD-CELLS-OPTION.svg" width="60" height="60" border="0" alt="WIRELESS" /></a></div> <div style="display: inline-block; margin-right: 2px;" data-toggle="tooltip" data-original-title="Based on the limitation of electrical energy provided to an equipment"><a class="options" href="/en/load-cells-options/atex-iecex-csa-intrinsically-safe-load-cells "><img src="//files.sensy.com/Illustration Options/EN/ATEX-IECEX-CSA-INTRINSICALLY-SAFE-LOAD-CELLS-OPTION.svg" width="60" height="60" border="0" alt="EXi" /></a></div> <div style="display: inline-block; margin-right: 2px;" data-toggle="tooltip" data-original-title="Operating or compensated temperature (to be define)"><a class="options" href="/en/load-cells-options/low-temperature-load-pins-50-180-option "><img src="//files.sensy.com/Illustration Options/EN/LOW-TEMPERATURE-LOAD-PINS-50-180-OPTION.svg" width="60" height="60" border="0" alt="-50+180" /></a></div> <div style="display: inline-block; margin-right: 2px;" data-toggle="tooltip" data-original-title="Protection rating"><a class="options" href="/en/load-cells-options/degree-of-protection-load-pins-ip67 "><img src="//files.sensy.com/Illustration Options/EN/DEGREE-OF-PROTECTION-LOAD-PINS-IP67-OPTION.svg" width="60" height="60" border="0" alt="IP67" /></a></div> </div> |
5900
THROUGH HOLE (ANNULAR) LOAD CELLS
<p>Annular force transducers specially designed for applications requiring a load mesurement through a centred hole.</p> <p>o Sturdy design<br />o Material: stainless steel<br />o Protection class: IP67<br />o Easy to install<br />o CE certified for hoisting applications<br />o Complete range of "CE" certified electronics and load limiters<br />o Cable length: 6 m (other lengths available on request)</p> <p></p> <div style="padding-top: 20px; margin-bottom: -30px;"> <p style="font-weight: bold; margin-bottom: 12px; color: #389be1;">AVAILABLE OPTIONS</p> <div style="display: inline-block; margin-right: 2px;" data-toggle="tooltip" data-original-title="Two independent Wheatstone bridges equipped with strain gauges"><a class="options" href="/en/load-cells-options/dual-bridge-load-cells-option "><img src="//files.sensy.com/Illustration Options/EN/DUAL-BRIDGE-LOAD-CELLS-OPTION.svg" width="60" height="60" border="0" alt="DUAL-BRIDGE" /></a></div> <div style="display: inline-block; margin-right: 2px;" data-toggle="tooltip" data-original-title="Safety Integrity Levels (EN 62061 standard) or PL (Performance Levels - ISO 13849 standard)"><a class="options" href="/en/load-cells-options/sil-load-pins-load-cells-safety-integrity-levels-option "><img src="//files.sensy.com/Illustration Options/EN/SIL-PL-READY-LOAD-PINS-LOAD-CELLS-OPTION.svg" width="60" height="60" border="0" alt="SIL-PL" /></a></div> <div style="display: inline-block; margin-right: 2px;" data-toggle="tooltip" data-original-title="see : Analogue amplifiers"><a class="options" href="/en/load-cells-options/load-cell-EMBEDDED-ANALOGUE-AMPLIFIER-option"><img src="//files.sensy.com/Illustration Options/EN/EMBEDDED-STRAIN-GAUGE-AND-LOAD-CELL-SIGNAL-CONDITIONER-AMPLIFIER-OPTION.svg" width="60" height="60" border="0" alt="AMPLIFIED-OUTPUT" /></a></div> <div style="display: inline-block; margin-right: 2px;" data-toggle="tooltip" data-original-title="see : DIGITAL CONVERTERS"><a class="options" href="/en/load-cells-options/load-cell-EMBEDDED-DIGITAL-CONVERTER-option"><img src="//files.sensy.com/Illustration Options/EN/EMBEDDED-LOAD-CELL-AND-DIGITAL-STRAIN-GAUGE-CONVERTER-OPTION.svg" width="60" height="60" border="0" alt="DIGITAL-OUTPUT" /></a></div> <div style="display: inline-block; margin-right: 2px;" data-toggle="tooltip" data-original-title="Wireless"><a class="options" href="/en/load-cells-options/wireless-load-pins-load-shackles-load-cells-option "><img src="//files.sensy.com/Illustration Options/EN/WIRELESS-LOAD-PINS-LOAD-SHACKLES-LOAD-CELLS-OPTION.svg" width="60" height="60" border="0" alt="WIRELESS" /></a></div> <div style="display: inline-block; margin-right: 2px;" data-toggle="tooltip" data-original-title="Based on the limitation of electrical energy provided to an equipment"><a class="options" href="/en/load-cells-options/atex-iecex-csa-intrinsically-safe-load-cells "><img src="//files.sensy.com/Illustration Options/EN/ATEX-IECEX-CSA-INTRINSICALLY-SAFE-LOAD-CELLS-OPTION.svg" width="60" height="60" border="0" alt="EXi" /></a></div> <div style="display: inline-block; margin-right: 2px;" data-toggle="tooltip" data-original-title="Operating or compensated temperature (to be define)"><a class="options" href="/en/load-cells-options/low-temperature-load-pins-50-180-option "><img src="//files.sensy.com/Illustration Options/EN/LOW-TEMPERATURE-LOAD-PINS-50-180-OPTION.svg" width="60" height="60" border="0" alt="-50+180" /></a></div> <div style="display: inline-block; margin-right: 2px;" data-toggle="tooltip" data-original-title="Protection rating"><a class="options" href="/en/load-cells-options/degree-of-protection-load-pins-ip67 "><img src="//files.sensy.com/Illustration Options/EN/DEGREE-OF-PROTECTION-LOAD-PINS-IP67-OPTION.svg" width="60" height="60" border="0" alt="IP67" /></a></div> <div style="display: inline-block; margin-right: 2px;" data-toggle="tooltip" data-original-title="Connector output"><a class="options" href="/en/load-cells-options/load-pin-with-connector-option "><img src="//files.sensy.com/Illustration Options/EN/LOAD-PIN-WITH-CONNECTOR-OPTION.svg" width="60" height="60" border="0" alt="CONNECTOR-OPTION" /></a></div> </div> |